The Arkel ARL 500 elevator control panel complies with EN 81-1/2+A3 standards. It operates at speeds of up to 2.5 m/s and supports up to 48 stops for both hydraulic and traction elevators.
TECHNICAL SPECIFICATIONS
- Door Control
- Compatible with all types of automatic doors.
- One door control input/output in the revision box and two in the control panel.
- Door bridging circuit on the control board enables early door opening and door open level correction.
- Motor-Phase Protection
- Protection Systems:
- Built-in motor protection with dedicated input/output on the control board.
- Cabin and shaft power supply fuses with leakage current protection.
- Special connections for safety circuits in the control panel, revision box, and pit box.
- Shaft lighting control using a pulse current switch, operable via buttons on the cabin top and shaft bottom.
- Protection Systems:
FUNCTIONS
- Independent door control for each stop with dual door support.
- Serial cabin communication via the CANbus line.
- Direct connection between the control panel and revision box using flat, socketed cables.
- Plug-and-play connection between the cabin control panel and the revision box with a single socketed cable.
- Serial floor communication via the CANbus line.
- Shaft-wide CANbus system with modular socketed cables connecting floors.
- Plug-and-play connection for door contact circuits and floor door interlock contacts at each floor.
- Single cable socketed connection with the pit box.
- Integrated AKUS-SD floor-leveling system within the panel.
- Emergency lowering system for hydraulic elevators with the addition of an ARL-SARJ board and two 12V batteries.
- Special test function for verifying cabin and floor control panel connections.
- Control of the ARL-500 motherboard and ADrive speed controller from any point via a handheld terminal connected to the CANbus line.
- Emergency alarm siren operable from the cabin top and shaft bottom buttons.