The ARCODE elevator control panel complies with EN 81/1-2/20+A3 standards and supports speeds of up to 4 m/s, capable of operating in hydraulic and traction elevators with up to 64 stops.
TECHNICAL SPECIFICATIONS
- Door Control
- Compatible with all types of automatic doors.
- Includes:
- 1 door control input/output in the revision box.
- 2 door control input/outputs in the control panel.
- Motor and Phase Protection
- Integrated motor phase protection.
- Cabin and shaft power supply protected with leakage current fuses.
- Pulse current switch for shaft lighting control (operable from cabin top and shaft bottom).
- Emergency Systems
- Emergency alarm siren, operable from both cabin top and shaft bottom buttons.
- Dedicated safety circuit connections in the control panel, revision box, and pit box.
- Remote Management
- ARCODE system controllable from any location via a handheld terminal connected to the CANbus network.
FUNCTIONS
- Communication
- Serial cabin communication over the CANbus line.
- Serial floor communication over the CANbus line or parallel floor connection via the MSP16 card.
- Modular shaft-wide CANbus system with socketed cables for floor-to-floor connectivity.
- Modular Connections
- Flat, socketed cable connection between the control panel and revision box.
- Plug-and-play connection between the cabin panel and revision box via a single socketed cable.
- Floor button panels connected using socketed cables at each floor via the CANbus system.
- Modular door contact circuit with floor-to-floor connectivity using socketed cables.
- Plug-and-play connection for door interlock contacts at each floor.
- Single socketed cable connection to the pit box.
- Door and Floor Management
- Dual-door support for independent door control at each stop.
- Direct stopping functionality for improved performance on short floors.
- Rescue Operations
- Supports easy directional floor rescue using a single-phase 220VAC UPS or a battery pack.